System Composition
The system consists of three parts: RF card, system management unit, and well irrigation controller.
II. Technical Specifications
-
Applicable pump power: ≤ 11KW (for higher-power pumps, an additional starter cabinet is required)
-
Operating voltage: 380V ± 10%
-
RF card: Compliant with ISO/IEC14443A protocol, 32-bit unique serial number
-
Operating frequency: 13.56MHz; communication rate: 106 KBPS; sensing distance: ≤ 10cm
-
Unit price setting: Accurate to two decimal places (0.00 currency unit)
-
Display: Chinese character LCD display; maximum recharge display: 8 digits (999,999.99)
⚠️ Do not open the cover while powered on.
III. Functional Features of the Well Irrigation Controller
-
Tiered water pricing – Supports three-level, four-tier water pricing plus electricity pricing, enabling progressive pricing to meet agricultural water pricing reform requirements.
-
Flexible metering configuration – Supports water‑only/electricity‑only or dual metering, single‑control/dual‑control, unit price setting, and tiered water pricing, all configurable to meet various metering and control needs.
-
Multi‑card/multi‑well flexibility – Supports multiple cards per well, one card for multiple wells, or well‑specific authorization cards (for 1–30 households per well).
-
Card‑controlled pump start/stop – Tap the card to start or stop the pump; the system automatically meters and deducts charges according to the preset unit price.
-
Comprehensive protection – Includes motor phase‑loss protection, overload protection, and short‑circuit protection.
-
Electricity‑to‑water conversion – Calculates and displays water consumption based on electricity usage using a preset water‑electricity coefficient, eliminating the need for a separate flow meter.
-
LCD display – Shows total water consumption, total water cost, total electricity consumption, total electricity cost, and water quota utilization percentage in Chinese characters.
-
Configurable low‑balance alert – Helps users monitor water usage and recharge in time without interrupting operation.
-
Smart card identification – Automatically identifies illegal or counterfeit cards to prevent management loopholes.
-
Historical record function – Supports balance inquiry for lost cards, replacement card issuance, and invalidation of reported lost cards to prevent fraudulent use.
-
Unsettled card reminder on startup – Displays a reminder if a previous user's card was not properly settled, facilitating management for both users and administrators.
-
Balance inquiry during operation – While one user is operating the device, other users can tap their cards to check their own balance without affecting the current user's operation.
-
Anti‑theft protection (bypass prevention) – Detects electricity or water theft and automatically cuts off the high‑voltage power supply upon detection. (Note: Requires the installation of a synchronous smart power management box.)
-
Remote data transmission – Supports (with optional communication module) real‑time transmission of water usage data and well extraction data.
-
Local & remote control – Supports local control and, with the communication module, remote on/off control via mobile APP or PC.
-
Remote parameter setting – Supports (with communication module) remote configuration of water quotas, water prices, and other parameters.
-
Enclosed ABS casing – Splash‑proof, dust‑proof, and insect‑proof for reliable outdoor use.
IV. Functional Features of the System Management Unit
-
PC version – Runs on Windows operating system with a Chinese graphical interface and a large‑capacity database.
-
Standalone version – Operates without a computer, with Chinese character prompts for easy operation.
-
Large‑scale management – Manages up to 50,000 well irrigation controllers and issues/ manages up to 50,000 RF cards.
-
Village code locking – The village code cannot be changed, preventing cross‑village recharge management issues.
-
Pulse constant locking – The pulse constant cannot be altered, avoiding metering inaccuracies due to accidental changes.
-
Recharge statistics – Provides recharge amount statistics for clear account management, preventing misappropriation by administrators or operators.
-
Two‑level authority management – Clearly distinguishes between administrator and operator permissions; operators have usage rights only.
-
Password recovery function – Allows administrators to recover forgotten passwords without affecting system operation, maximizing user‑friendliness.